Mini split size calculator

Find the mini split capacity your room needs. Enter the floor area and conditions, and we match the load to a standard single-zone size.

Your space

Units
Or fill in length and width below and we work out the area.
Sun exposure
Is the space a kitchen?

Mini split sizing

—
BTU per hour
Chart value for this area
—
Area used
—
Same load in tons
—
Same load in kW
—
Recommended: —

Quick answer: most bedrooms need a 9,000 BTU mini split, living rooms up to 550 sq ft need 12,000 BTU, and open spaces of 700 to 1,000 sq ft need 18,000 BTU. Sunny rooms, high ceilings and hot climates push you up a size.

Mini split sizes and the area they cover

This is the largest floor area each standard size covers in normal conditions, using the ENERGY STAR chart and our 95% rule. Treat it as the upper limit, not a target.

Mini split size (BTU)TonsCovers, normal conditions
6,0000.5up to about 250 sq ft
9,0000.8up to about 400 sq ft
12,0001up to about 550 sq ft
18,0001.5up to about 1,000 sq ft
24,0002up to about 1,500 sq ft
30,0002.5up to about 2,000 sq ft
36,0003up to about 2,500 sq ft

Mini split size by square feet

Pick your room size for a worked example with sun, climate, ceiling and occupancy scenarios already calculated.

Why mini split sizing is a little different

Most mini splits use an inverter compressor that slows down instead of switching off. That makes them more forgiving than a window unit, but it does not make oversizing free. An inverter unit has a minimum speed, and a head that is far too big for the room still cycles at that minimum. You lose the steady, quiet dehumidifying run that makes mini splits comfortable.

Each indoor head also only cools the room it is in. A 24,000 BTU unit in the living room will not cool the bedrooms down the hall, even though the total BTUs look right on paper. If the rooms are separated by walls and doors, size each room on its own.

Heating with a mini split

This calculator sizes for cooling. If the unit is your main heat source in a cold climate, check its heating output at your winter design temperature. Cold-climate models list capacity at 5°F or lower in the spec sheet. In cold regions the heating load often decides the size.

How this calculator works

The starting point is the room sizing chart that ENERGY STAR publishes for room air conditioners. It gives a capacity in BTU per hour for each band of floor area, and it assumes an 8-foot ceiling. We then apply these adjustments, in this order:

  • Sun: heavily shaded rooms take 10% off, very sunny rooms add 10%. These two figures come from ENERGY STAR.
  • Climate: cool summers take 10% off, hot climates add 10% and very hot or desert climates add 20%. ENERGY STAR does not publish a climate factor; this one is ours and is deliberately modest.
  • Insulation: well insulated rooms take 10% off and poorly insulated ones add 15%. This is also our own adjustment.
  • Ceiling height: above 8 feet we scale by the extra volume, so a 10-foot ceiling adds 25%.
  • People: add 600 BTU for each person beyond two who regularly uses the room (ENERGY STAR).
  • Kitchen: add 4,000 BTU if the unit cools a kitchen (ENERGY STAR).

The result is rounded to the nearest 100 BTU. For mini splits we then pick the smallest standard capacity that covers at least 95% of the load, because inverter units can run harder for short periods and an oversized unit short-cycles and leaves the air clammy.

This is a room-by-room estimate, not a Manual J calculation. For a whole house, new ductwork or a system over 36,000 BTU, ask a licensed contractor to do a Manual J load calculation before you buy.

Frequently asked questions

What size mini split do I need for 500 square feet?

About 12,000 BTU for a room with normal sun and an 8-foot ceiling. Go up to 18,000 BTU if the room is very sunny, has a high ceiling or you live in a hot climate. See the 500 sq ft page for the full breakdown.

Is it OK to undersize a mini split a little?

Slightly, yes. Inverter mini splits can run above their nominal rating for short periods, which is why we accept a unit that covers 95% of the load. Going further under means the room may not hold temperature on the hottest days.

Single-zone or multi-zone?

One open room up to roughly 1,000 to 1,500 sq ft is usually best served by a single-zone unit. Separate rooms with doors need a head in each room, either from several single-zone units or one multi-zone outdoor unit.

What sizes do mini splits come in?

Common single-zone sizes are 9,000, 12,000, 18,000, 24,000, 30,000 and 36,000 BTU. Some brands also sell 6,000 BTU heads for small rooms, and multi-zone outdoor units go to 48,000 BTU and beyond.

Does a mini split need a 240V circuit?

Most units of 18,000 BTU and above run on 208 to 240V. Some 9,000 and 12,000 BTU models run on 115 to 120V. Check the nameplate and have an electrician size the breaker and wire from its MCA and MOP ratings.