Quick answer: a 300 sq ft room with normal sun and an 8-foot ceiling needs about 7,000 BTU per hour. A 500 sq ft room needs about 12,000 BTU, and a 1,000 sq ft space about 18,000 BTU.
What a BTU means for an air conditioner
A BTU, or British thermal unit, is the heat needed to warm one pound of water by one degree Fahrenheit. Air conditioners are rated in BTU per hour: how much heat they can pull out of a room in an hour. A 12,000 BTU unit removes 12,000 BTU of heat every hour it runs at full output.
The number that matters is how much heat flows into your room on a hot afternoon. Sunlight through windows, warm walls and roof, people, lights and appliances all add to it. The air conditioner has to match that heat gain. If it falls short, the room never reaches your thermostat setting. If it is far bigger, it cools in short bursts and leaves humidity behind.
BTU chart by room size
These are the values from the ENERGY STAR sizing chart, which assumes an 8-foot ceiling and average conditions. The mini split column shows the standard capacity that covers each band.
| Floor area (sq ft) | BTU per hour | Mini split size | Tons |
|---|---|---|---|
| 100 to 150 | 5,000 | 6,000 BTU | 0.4 |
| 150 to 250 | 6,000 | 6,000 BTU | 0.5 |
| 250 to 300 | 7,000 | 9,000 BTU | 0.6 |
| 300 to 350 | 8,000 | 9,000 BTU | 0.7 |
| 350 to 400 | 9,000 | 9,000 BTU | 0.8 |
| 400 to 450 | 10,000 | 12,000 BTU | 0.8 |
| 450 to 550 | 12,000 | 12,000 BTU | 1 |
| 550 to 700 | 14,000 | 18,000 BTU | 1.2 |
| 700 to 1,000 | 18,000 | 18,000 BTU | 1.5 |
| 1,000 to 1,200 | 21,000 | 24,000 BTU | 1.8 |
| 1,200 to 1,400 | 23,000 | 24,000 BTU | 1.9 |
| 1,400 to 1,500 | 24,000 | 24,000 BTU | 2 |
| 1,500 to 2,000 | 30,000 | 30,000 BTU | 2.5 |
| 2,000 to 2,500 | 34,000 | 36,000 BTU | 2.8 |
See the full BTU sizing chart for central air and window unit sizes, or jump to a specific room size on the mini split size by square feet page.
How to measure your room
- Measure the length and width of the floor in feet. Round to the nearest half foot: 12 feet 6 inches is 12.5 feet.
- Multiply length by width to get square feet. A 14 by 16 foot room is 224 sq ft.
- For an L-shaped room, split it into two rectangles, work out each one and add them together.
- If the room is fully open to another space with no door, include that space too. The cold air will spread into it.
When to adjust the result
Pick very sunny for rooms with large west or south-facing windows that get afternoon sun, or rooms under an uninsulated roof. Pick heavily shaded if trees or other buildings block the sun most of the day. Choose the climate that matches your hottest summer weeks, not the average day. A home office with a gaming PC and two monitors can add as much heat as an extra person or two.
How this calculator works
The starting point is the room sizing chart that ENERGY STAR publishes for room air conditioners. It gives a capacity in BTU per hour for each band of floor area, and it assumes an 8-foot ceiling. We then apply these adjustments, in this order:
- Sun: heavily shaded rooms take 10% off, very sunny rooms add 10%. These two figures come from ENERGY STAR.
- Climate: cool summers take 10% off, hot climates add 10% and very hot or desert climates add 20%. ENERGY STAR does not publish a climate factor; this one is ours and is deliberately modest.
- Insulation: well insulated rooms take 10% off and poorly insulated ones add 15%. This is also our own adjustment.
- Ceiling height: above 8 feet we scale by the extra volume, so a 10-foot ceiling adds 25%.
- People: add 600 BTU for each person beyond two who regularly uses the room (ENERGY STAR).
- Kitchen: add 4,000 BTU if the unit cools a kitchen (ENERGY STAR).
The result is rounded to the nearest 100 BTU. For mini splits we then pick the smallest standard capacity that covers at least 95% of the load, because inverter units can run harder for short periods and an oversized unit short-cycles and leaves the air clammy.
This is a room-by-room estimate, not a Manual J calculation. For a whole house, new ductwork or a system over 36,000 BTU, ask a licensed contractor to do a Manual J load calculation before you buy.
Frequently asked questions
How many BTUs do I need per square foot?
For a typical room with an 8-foot ceiling, the ENERGY STAR chart works out to roughly 20 to 30 BTU per square foot for small rooms and 15 to 20 for larger open spaces. Small rooms need more per square foot because walls and windows make up a bigger share of the heat gain.
Is it better to buy a bigger air conditioner?
No. An oversized unit cools the air quickly and shuts off before it has removed much humidity, so the room feels cold and damp. It also cycles on and off more often, which wastes energy and wears the compressor. Buy the size the room needs.
Does this calculator work for heating?
It sizes cooling. Heat pumps are usually chosen by cooling load in moderate climates, but in cold climates the heating load is often larger. Check the unit's heating capacity at your local winter design temperature.
What if my room has a very high or vaulted ceiling?
Enter the average ceiling height. We scale the load by the extra air volume above 8 feet, so a 12-foot ceiling adds 50%. Very tall spaces with skylights should get a professional load calculation.
How do I convert BTU to tons?